On-site Services:
Installation and Testing:
·Arrival inspection; lifting instruction; Coarse alignment; Piping engineering installation; Control signal detection.
Routing Maintenance:
·Level Ia(400H) maintenance
·Tighten all bolts;Check Insulation monitoring;Testing;
·Water cooling the motor to detect leakage;Analyze bearing temperature and vibration; parameter;Analyze variable-frequency voltage temperature detecting device, dehydration plant;Check circuit and the ground connection for frequency conversion power cabinet.
·Clean and exam deionzed water electric conductivity; Check pump productivity, contactor performance and battery working capacity.
Level Ib(800H) maintenance
·Contents in Level Ia maintenance are included;Check and replace bearing and bearing bush;Sampling the oil.
Upgrading:
·Parts upgrading;System troubleshooting;Replace and Trial running for searching units